Jerry Brown Domestic Electrician Telephone: (01684) 567565 |
|
|
The following are some of the items found in a bathroom and where they should be located
|
Zones |
Wall Mounted Switch |
Light 230v |
Pull Cord Switch |
12 volt Light |
Instlating Pull Cord |
12 volt Transformer |
Shaver Supply Unit |
Fixed Fan 230 volt |
Fixed Fan 12 volf |
Shower Pump |
Water Heater |
|
0 |
ⓝ
|
ⓝ
|
ⓝ
|
ⓝ
|
ⓨ Note 1 |
ⓝ
|
ⓝ
|
ⓝ
|
ⓝ
|
ⓝ
|
ⓝ
|
|
1 |
ⓝ
|
ⓨ Note 2 |
ⓝ
|
ⓨ
|
ⓨ Note 3 |
ⓝ
|
ⓝ
|
ⓨ Note 2 |
ⓨ Note 3 |
ⓨ Note 3 |
ⓨ Note 3 |
|
2 |
ⓝ
|
ⓨ Note 3 |
ⓝ
|
ⓨ
|
ⓨ Note 3 |
ⓝ
|
ⓨ Note 4 |
ⓨ Note 3 |
ⓨ Note 3 |
ⓨ Note 3 |
ⓨ Note 3 |
|
3 |
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ Note 4 |
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
|
Outside |
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
ⓨ
|
Notes.
1. 12 volt only and must be IP X7
2. Not able to be located elsewhere and must be 30mA R.C.D. protected and IP X4 (IP X5 if hosing down)
3. IP X4 level of protection required (IP X5 if hosing down)
4. Shaver supply unit, complying with BS EN 60742 Chapter 2, Section 1.